Testing standard: EN 55032, EN 55024, EN 61000-3-2, EN 61000-3-3
Emc directive: 2014/53/EU
EMI part of test project:
1. Conduction (CE) 0.15~30MHz EN 550322. Telecommunication terminal conduction (ISN) 0.15~30MHz EN 550323. Space radiation (RE) : 30MHz~6GHz EN 55032If the maximum frequency of the source inside the product is lower than 108MHz, the measurement is only carried out to 1GHz;If the highest internal source frequency of the product is between 108MHz and 500MHz, the measurement is carried out to 2GHz.If the highest frequency of the internal source of the product is between 500MHz and 1GHz, the measurement shall be carried out to 5GHz.If the maximum frequency of the internal source of the product is higher than 1GHz, the measurement shall be carried out to 5 times or 6GHz of the maximum frequency, whichever is smaller;Harmonic: the standard EN 61000-3-2 rated voltage range is AC220~240V.This item tests rated power 75W and below the product infinite value stipulation, need not test.5. Voltage fluctuation and Flicker: the rated voltage range of standard EN 61000-3-3 is AC220~240V. This project is required.Test limit requirements: short-term scintillation value Pst≤1.0;Long-term scintillation value Plt≤0.65;Relative steady-state voltage variation dc≤3.3%;Maximum corresponding voltage variation dmax≤4%.
EMS test items: the following EMS test levels are standard general requirements.
1. ESD standard: EN 55024 (iec61000-4-2);Performance criterion: grade B;Contact discharge: ±4kV;Each discharge point has a polarity of 25 times.Air discharge: ±8kV;Each discharge point has a polarity of 10 times.2. Radiation immunity (RS) standard: EN55024 (iec61000-4-3);Performance criterion: grade A;Frequency range: 80~1000MHz frequency range and above;3. EFT standard: EN55024 (iec61000-4-4);Performance criterion: grade B;AC power supply input terminal: 1kV.Repetition rate: 5kHz;DC power supply input terminal: 0.5kV.Repetition rate: 5kHz; Signal port and telecommunication port: 0.5kV.Repeat frequency 5kHz (no test is required for ports connected to data cables of an expected length not more than 3m as specified by the manufacturer);4. Surge
Performance criterion: grade B;Test specification: AC input: 1.2/50(8/20) composite wave;Line-line: 1kV;Line-to-ground: 2kVDC input: 1.2/50(8/20) composite wave;0.5kV (for ports that may be connected directly to outdoor cables according to manufacturer's specifications only)Signal port and telecommunication port: 10/700 waveform;1kV or 4kV (only applicable to ports that may be connected directly to outdoor cables according to manufacturer's specificationsPort voltage applied without protector is generally 1KV);5. Conductive disturbance immunity (CS)Performance criterion: grade ATest voltage: 3V/10V6. Power frequency magnetic field immunity (MS)Performance criterion: grade A;Test voltage: 3A/m;10 a/m;A/m;100 a/m, etc.;7. Voltage sag, short interruption immunity (Dips)Performance criterion: grade B /C;
EMS performance criterion
Performance criterion A:Without operator intervention, the equipment should continue to work as expected.When the equipment is used as expected, it is not allowed to perform below the performance specified by the manufacturerLevel 1 performance degradation or loss of functionality.Performance levels can be replaced with allowable performance degradation.If the manufacturer does not specify minimum performance levels and permitsPerformance degradation can be learned from the product manual or technical documentation, and the user can reasonably expect the equipment used to meet this requirement.
Performance criterion B:After the beginning of the test, the equipment should continue to work as expected without the intervention of operators.When the device is used as intended, after harassment,Performance degradation or loss of functionality below manufacturer's requirements is not allowed.Performance levels can be replaced with allowable performance degradation.During the trial,Performance degradation is allowed.After the test, however, the working state should not change and the stored data should not be lost.If the manufacturer does not specify the minimumThe capability level and allowable performance degradation is known from the product specification or technical documentation, and the user can reasonably request the equipment used to achieve thisRules.
Performance criterion C:Allow loss of function that can be recovered by itself or that can be restored by the user following the manufacturer's instructions.Stored in non-volatile memoryFunctions and/or information that are protected by the spare battery shall not be lost.